Lion 500 Alcolmeter

- Simple to use the lion alcolmeter is fully automatic
- Fast accurate analysis
- Easy to read display
- Last Test Recall
- True Evidential Capability
- Calibration
- Ergonomic Design
- Low power consumption
- Simple, Low cost mouthpiece
| Model | Lion 500 |
| Analytic Principle | Lion fuel censor for alcohol analysis. Unaffected by acetone, hydrocarbons, non-alcoholic food and drug vapours, and all other likely breath contaminants. |
| Measure Range | 0.02 to 2.00mg/litre; .005 to .400% BAC (g/210 litres). An over-range option is given at higher levels. An optional Zero, Pass, Warn, Fail readout is also available. |
| Breath Sampling | The 500 automatically samples deep-lung air. An optional manual override feature may also be used if required. |
| Analytical Response Time | Normally within 30 seconds at the ‘zero’ alcohol level |
| Recovery Time | Approximately 100 seconds at 0.50mg/l |
| Operating Temperature (Optimum) | -5˚C to +40˚C |
| Storage Temperature | -20˚C to +65˚C |
| Power supply | 2 x AAA cells provide sufficient power for around 400 breath tests. Two stage low power warning system. |
| Humidity | 10 to 95%, non-condensing |
| Barometric Pressure | 600 to 1,300hPa |
| Calibration | Recommended every 6 months, using either a wet-bath simulator, or an AlcoCal dry-gas standard. Automatic, security-protected procedure. |
| Display | LCD graphics, dimensions 45mm x 21mm, 128 x 64 pixels, with backlighting |
| Audible Beeper | Gives auxiliary warning messages |
| Microcontroller | H8/3664 |
| Memory | The last test is stored memory, for later recall if required, even after switching |
| Warm-up time | The instrument is not heated, so there is no warm-up time at any ambient temperature |
| Disposable mouthpiece | Simple disposable ‘pressure’ tube, the same as used with the S-D2/S-L2 |
| RFI Certification | Exceeds requirements of EN 50081-1:1992 (emission) and EN 50082-1:1997 (immunity). In the UK, complies with the Home Office/ACPO 2002 requirements in respect of immunity TETRA |
| Vibration and shock | Meets IEC 68-2-27 Part 2.1 Test EA and IEC 68-2-6 Part 2.1 Test FC |
| Case Construction | Impact resistant ABS |
| Exterior Dimensions (W x D x H) | 125 x 654 x 15mm |
| Weight | Approximately 140g, including batteries |
AloCal-M
Designed to read breath alcohol at a high level of accuracy.
- WEIGHT: 0.120kg
- DIMENSIONS: 223x66mm
- Shelf life of 6 months
- Maximum filling pressure 10.0 bar
- Number of samples approx. 50
- Accuracy ± 10% of stated alcohol concentration
- Supplied with explanatory booklet
Includes:
- Low pressure disposable canister
- Dispensing cap with connector tube
- Typically used by customers with single instrument and a low test rate
AlcoCal 2AL
Designed to read breath alcohol at a high level of accuracy.
- Includes regulator and 10 AlcoCal® connector tubes
- WEIGHT: 0.758kg
- DIMENSIONS: 283x74mm
- Shelf life estimated from 24 to 36 months
- Maximum filling pressure 34.5 bar
- Number of samples approx. 300
- Accuracy ± 3% of stated alcohol concentration
- Supplied with explanatory booklet and 10 connector tubes
Includes:
- High pressure disposable cylinder
- Re-usable regulator/contents gauge
Nasal Tubes
- Pack of 500
Protective Pouch
- Grey – For use with Lion 500
Protective Pouch
- Yellow – For use with Lion 500